Add scripts
This commit is contained in:
52
scripts/scripts_PaR/RUN_PAR.tcl
Normal file
52
scripts/scripts_PaR/RUN_PAR.tcl
Normal file
@@ -0,0 +1,52 @@
|
||||
### This is a sample RUN TCL file to control the stages of the digital ASIC BE flow
|
||||
### We are using RTL Compiler (synthesis) and Encounter (PaR) from the the Cadence Inc.
|
||||
### The current technology is XFAB 180nm
|
||||
|
||||
### For current flow the following assumptions are expected:
|
||||
### - set all USER settings;
|
||||
### - check that netlist and exported synthesis SDC are exisits with consistent names;
|
||||
### - open the terminal
|
||||
### - cd to the main folder with the scripts, src, reports etc. (BE_ASIC_DESIGN_CADENCE_SCRIPTS folder) and then cd to the ./WORK_TMP_FOLDER
|
||||
### - run Place-and-Route with Encounter by typing in the same terminal "Encounter ../scripts/scripts_PaR/RUN_PAR.tcl"
|
||||
|
||||
|
||||
|
||||
### ================= USER SETTINGS =================
|
||||
set NETLIST_TOP_NAME "PWM_syn_netlist.v"; # RTL top module name
|
||||
set NETLIST_PATH "../results/results_syn"; # RTL path to the source files
|
||||
|
||||
set PAR_SDC_TOP_NAME "PWM_syn.sdc"; # SDC top file name
|
||||
set PAR_SDC_PATH "../results/results_syn"; # SDC path to the sources
|
||||
|
||||
set PAR_MMMC_FILE "../scripts/scripts_aux/XFAB180_MMMC.tcl"; # Multi-mode multi-corner file
|
||||
set PAR_NETLIST_TOP_PORT_FILE "../scripts/scripts_aux/PaR_NETLIST_TOP_PORT_FILE"; # Synthesis corner (typ by default)
|
||||
|
||||
set PAR_INIT_LEF_FILESET "/Cadence/Libs/X_FAB/XKIT/xt018/cadence/v7_0/techLEF/v7_0_1_1/xt018_xx43_MET4_METMID_METTHK.lef \
|
||||
/Cadence/Libs/X_FAB/XKIT/xt018/diglibs/D_CELLS_HD/v4_0/LEF/v4_0_0/xt018_D_CELLS_HD.lef \
|
||||
/Cadence/Libs/X_FAB/XKIT/xt018/diglibs/D_CELLS_HD/v4_0/LEF/v4_0_0/xt018_xx43_MET4_METMID_METTHK_D_CELLS_HD_mprobe.lef";
|
||||
|
||||
set PAR_REPORTS_FOLDER "../reports/reports_PaR"; # Reports folder
|
||||
set PAR_RESULTS_FOLDER "../results/results_PaR"; # Results folder
|
||||
|
||||
set FLOORPLAN_DIMENSIONS {200 200}; # FP chip area
|
||||
set FLOORPLAN_MARGINS {50 50 50 50}; #FP chip margins
|
||||
### ================= END of USER SETTINGS =============
|
||||
|
||||
|
||||
|
||||
### ================== PROC to run PaR =================
|
||||
### Set TRUE/FALSE and re-source RUN_PAR.tcl again in the interactive Encounter TCL shell
|
||||
set PaR_INIT "TRUE";
|
||||
set PaR_FP "TRUE";
|
||||
set PaR_PWR "TRUE";
|
||||
set PaR_PLACE "TRUE";
|
||||
set PaR_CTS "TRUE";
|
||||
set PaR_ROUTE "TRUE";
|
||||
set PaR_FINAL "TRUE";
|
||||
set PaR_OUT "TRUE";
|
||||
### ============== END of PROC to run PaR ==============
|
||||
|
||||
source ../scripts/scripts_PaR/FLOW_PAR.tcl; # Source PaR steps from the user TCL file
|
||||
|
||||
# Open Encounter GUI
|
||||
win
|
||||
Reference in New Issue